T1 - Linear affine transformations between 3-lead (Frank XYZ leads) vectorcardiogram and 12-lead electrocardiogram signals
AU - Dawson, Drew
AU - Yang, Hui
AU - Malshe, Milind
AU - Bukkapatnam, Satish T.S.
AU - Benjamin, Bruce
AU - Komanduri, Ranga
N1 - Funding Information:
The authors thank the Center for Health Sciences (CHS), Oklahoma State University, Tulsa, OK, for the support of this work. In particular, the authors thank Dr J. Hess, Chief Operating Officer at CHS, for his strong support. One of the authors (RK) thanks AH Nelson, Jr, Endowed Chair in Engineering, for additional financial support. Special thanks are due to Mrs. Sharon Green for editorial assistance. The support of the National Science Foundation CMMI Division (grants nos. 0427840 and 0729552) is gratefully acknowledged.
Copyright:
Copyright 2010 Elsevier B.V., All rights reserved.
PY - 2009/11
Y1 - 2009/11
N2 - Background: Recent advances in computer graphics and wireless technologies have renewed interest in vectorcardiogram (VCG) signals that use fewer leads than the conventional 12-lead electrocardiogram (ECG) signals for medical diagnostic applications. However, most cardiologists are accustomed to the 12-lead ECG even though some of the leads are either nearly aligned with or derived from the others and consequently contain redundant information. The ability to transform from orthogonal 3-lead VCG to 12-lead ECG enables the use of fewer leads for signal analysis, computer visualization, and wireless transmission of signals. This can also improve mobility, albeit limited, to the patients. Materials and Methods: We present a statistical approach to transform 3-lead Frank VCG to 12-lead ECG signals and vice versa, based on Dower's pioneering work on lead tranformation. This approach enables compensation of baseline shifts and other constant biases present in long ECG data streams, so that the resulting statistical transforms can be more consistent and accurate. We compare the performance of the affine transform with that of Dower transform (from 3 to 12 and from 12 to 3) using the data from the PhysioNet PTB database. Results: The results show that for both myocardial infarction (MI) and healthy control (HC) subjects, the statistical affine transform presented here maps 3-lead VCG to12-lead ECG more accurately than Dower or other lead transformation matrices of the ECG recordings. Discussion: This investigation also shows the limitations associated with single dipole assumption that underlies Dower's geometric transformation. The results also indicate that lead transformation accuracy can be improved using separate customized transforms to, for example, age or pathologic conditions (here, MI vs HC) than a single statistical or geometric transform. Pertinently, we find that the affine transform coefficients can serve as discriminating features for classification/discrimination of MI patients from HC subjects.
AB - Background: Recent advances in computer graphics and wireless technologies have renewed interest in vectorcardiogram (VCG) signals that use fewer leads than the conventional 12-lead electrocardiogram (ECG) signals for medical diagnostic applications. However, most cardiologists are accustomed to the 12-lead ECG even though some of the leads are either nearly aligned with or derived from the others and consequently contain redundant information. The ability to transform from orthogonal 3-lead VCG to 12-lead ECG enables the use of fewer leads for signal analysis, computer visualization, and wireless transmission of signals. This can also improve mobility, albeit limited, to the patients. Materials and Methods: We present a statistical approach to transform 3-lead Frank VCG to 12-lead ECG signals and vice versa, based on Dower's pioneering work on lead tranformation. This approach enables compensation of baseline shifts and other constant biases present in long ECG data streams, so that the resulting statistical transforms can be more consistent and accurate. We compare the performance of the affine transform with that of Dower transform (from 3 to 12 and from 12 to 3) using the data from the PhysioNet PTB database. Results: The results show that for both myocardial infarction (MI) and healthy control (HC) subjects, the statistical affine transform presented here maps 3-lead VCG to12-lead ECG more accurately than Dower or other lead transformation matrices of the ECG recordings. Discussion: This investigation also shows the limitations associated with single dipole assumption that underlies Dower's geometric transformation. The results also indicate that lead transformation accuracy can be improved using separate customized transforms to, for example, age or pathologic conditions (here, MI vs HC) than a single statistical or geometric transform. Pertinently, we find that the affine transform coefficients can serve as discriminating features for classification/discrimination of MI patients from HC subjects.
KW - Dower transformation
KW - Electrocardiogram (ECG)
KW - Myocardial infarction (MI)
KW - Vectorcardiogram (VCG)
UR - http://www.scopus.com/inward/record.url?scp=70350057446&partnerID=8YFLogxK
U2 - 10.1016/j.jelectrocard.2009.05.007
DO - 10.1016/j.jelectrocard.2009.05.007
M3 - Article
C2 - 19608193
AN - SCOPUS:70350057446
SN - 0022-0736
VL - 42
SP - 622
EP - 630
JO - Journal of Electrocardiology
JF - Journal of Electrocardiology
IS - 6
ER -