Duodenal Perforation From IVC Filter Migration

Research output: Contribution to journalArticlepeer-review

Abstract

Herein we present a unique case of a penetrating arm of a migrated inferior vena cava (IVC) filter which resulted in acute, erosive upper gastrointestinal bleeding. The diagnosis was initially complicated by a previously placed hemostatic clip for prior gastrointestinal bleeding. Ultimately, the patient required an anterior duodenotomy for partial removal of the IVC filter and later required laser guided retrieval of the retained portion.
Original languageAmerican English
JournalOklahoma State Medical Proceedings
Volume8
Issue number3
StatePublished - 12 Dec 2024

Keywords

  • IVC filter
  • duodenal perforation
  • case report